Graphing
New Graph Types
...
JIRA | SUMMARY | DESCRIPTION | DETAILS |
---|---|---|---|
ORG-29592 | Icon improvements on left panel of Plot Details dialog | Much easier to tell a plot is a single plot or belongs to a group | In the past, when open a complicated graph to customize plot, it’s hard to tell if a plot is a single plot, or belongs to a group. For grouped plot, some Tabs only show when 1st member in the group is selected. In Origin 2025, a single plot is denoted by , a plot blonging to a group is denoted by alternatingicons |
ORG-29715 | Grouping plots gets easier | Group nonadjacent plots and create multi-groups | Change of behavior and context menus changes in Object Manager to make it easier to group plots in a layer
|
ORG-29949 | System variable for no element rescale when making new graphs | System variable @SLF to set fixed factor 1 when making new graphs with built-in or extended graph templates | In older versions, if user resize the graph page, or resize the layer in graph, the text label font size, the plot line and symbol thickness, the axis line thickness will rescale accordingly. This Scale Elements setting is a layer level property controlled on Size tab of Plot Details dialog. The default is Scale with Layer Frame. For users who want to keep font size, etc. no matter how you resize page or layer, go to Preferences: System Variables dialog. Set SLF value as 1. (0 by default). Workaround in older versions:
Note: User can also select Layer No Element Scaling theme and apply it to all existing graphs. And there is Graph: Fix Scale Factor… menu to set fixed factor for single graph. |
ORG-27177 | Data Slicer on Graph | Add data slicer to graph to filter data | Three ways to add data slicer on graph. Slicer is on graph so source worksheet will not be filtered.
Basic usage More options when right clicking on filter. E.g. right click a text type filter and check Multiple Selection so instead of a dropdown list, user can pick multiple items in column. Or right click to disable filter, delete filter or change filter to be another column Right click in blank area to add another filter Compare plots with different conditions For single layer graph, use Duplicate Plot option to add duplicate plots in same layer with different filter conditions for each plot Or duplicate into multiple layers with different filter conditions for each layer Add Filter to control all layers in graph For multi-layer graph, user can add filter to page level (check Common Filter for All layers/Plots) or to layer level (uncheck it) Set condition will affect all layers |
ORG-29671 | Easy way to change all plot’s X data in a layer or whole page | Change X context menu on Layer and Page level | Right click in blank area within layer and choose Change X to change all plot’s X to be certain column. Right click outside all layer frames and right click to change all plots in all layers' X to be certain column. Note: There was only Change X context menu on when right clicking on a plot. User would have to click each plot to change the X data or go to Plot Setup dialog to change so. It’s cumbersome. |
ORG-28659 | Error bar tooltip | The error bar tooltip provides numerical details of the range of uncertainty around data points in a graph. | The x and y error info shows when mousing over data points plotted with error bars, or when mousing over error bars. |
ORG-28723 | Swap layers or swap graph objects | Select position of two layers, or two graphic objects | Swap position dropdown list is added on mini toolbar if two layers, or two graphic objects are selected. It also shows on Object Edit toolbar on right side of workspace. E.g. shift+select two layers and click the button. |
ORG-28721 | Show Layer info in the Graphs list box | List Layer numbers in parenthesis after corresponding Graph name | This helps user to associate graphs and its layers in preview window when merging graphs |
ORG-29082 | Add Note for Layout Window | Adding notes for layout window from Object Manager | Notes could only be added to graph window in Origin 2024b. In Origin 2025, notes can be added to layout window as well. With Layout window active, click the Add Notes button on top of the Object Manager. If there is notes for a layout window, there will be + inside the icon. Click it to read the notes. |
ORG-28263 | 3 List orders in Batch Plotting Dialog | More ways to sort available books and sheets in Batch Plotting dialog | There was no sorting order option in Batch Plotting dialog. Before Origin 2024b, books show in creation order and sheets show in appearance order. In Origin 2024b, both books and sheets show in alphabetic order. In Origin 2025, 3 sorting modes are added. Click the column header to toggle them.
Note: Sheets in same book as source graph always show on top. |
ORG-28297 | Plot Menu for Image Window | Support plot menu for floating image window. | Float the image window to the other monitor then check the Plot menu |
ORG-29079 | Remove the limitation of 16 color toolbar icon for custom toolbar | Supoort 32bit color toolbar icon in custom toolbar | Before Origin2025, only 16 color toolbar icons are supported. If you choose a 24bit or 32bit color image for custom toolbar and restart Origin, you will get Button group bitmaps must be 16 color message. |
ORG-29031 | Histogram Auto Binning improvement for arithmetic sequences | Histogram Auto Binning improvement for arithmetic sequences | When count(unique(input))<=10, we can sort the unique(input) and check if they are arithmetic sequences. In an arithmetic sequence, the difference between consecutive terms is always the same. If they are arithmetic sequences, assume the difference between consecutive terms is delta, bin size=delta, bin begin should be min-delta/2, bin end is max+delta/2. Implemented in Origin2025. |
ORG-16510 | Smartly adjust ticks when zoom in the graph | Improve the rule of showing ticks to show better ticks values when zooming in | In Origin2025 before, improve the below case that sometimes too few ticks sometimes too many ticks
|
ORG-29595 | Enable Template Library Toolbar Button for Image Window | When image window is active, the menu “Plot → Extended Templates“ and Template Library button is available. | Import an image to image window then choose the menu “Plot → Extended Templates“ or Template Library button. |
...
JIRA | SUMMARY | DESCRIPTION | DETAILS |
---|---|---|---|
ORG-29391 | Copy All Open Branches as Image In Report Sheet | Context menu added on the hierarchical result sheet to copy all open branches as an image | Right click anywhere on result sheet and copy all open branches as an image. Then paste it to Word, Powerpoint, etc. |
ORG-26576 | Export Table on Hierarchical Report Sheet to ASCII | Context menu to directly export table as ASCII file | Right click on any table you want to export to ASCII and select Export ASCII…. Click the path created on Messages Log on left side of workspace to open the file. |
ORG-29511 | Analysis on Graph Data Filter | The graph with data filter will create virtual dataset. And the analysis will be performed on the virtual dataset. |
Limitation:
|
ORG-29736 | All Columns in Analysis Tools Issues |
| Tools with the Whole Sheet context menu: cnormalizeavecurves, rnormalize, integ1, smooth, plotvm, wstackcol XF and so oninterp1, paMultiY XF and most fitting tools like Linear Fit, Nonlinear Fit. Tools with the Add All Columns context menu: avecurves, interp1, paMultiY XF and most fitting tools like Linear Fit, Nonlinear Fitcnormalize, rnormalize, integ1, smooth, plotvm, wstackcol XF and so on. |
ORG-29483 | Hot Key to open Change Parameter Dialog | Ctrl+F10 or Ctrl+single click to open the change parameters dialog. | Ctrl+single click on green lock will open corresponding tool. Ctrl+F10 will follow the following rule:
|
ORG-28587 | Tooltip when hover over analysis report sheet tab | Check the report sheet top table name and input data in tooltip when hover over analysis report sheet tab. Could also right click the report sheet tab and choose Name, Notes, Color context menu to check the full name if it’s long. | |
ORG-29389 ORG-29977 | Customize Report Sheet Table Style |
| Choose main menu Preference: Report Style: Open Dialog to open Report Style dialog to customize: |
...