Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • ORG-9842 - PDF export fails on worksheet with 3D OpenGL graph embedded as EMF on some PCs.
    The worksheet has same graph embedded once as EMF and once as BMP. Export the worksheet as Image File and choose PDF. The cell embedded as EMF is messed up in the exported PDF file. This was working in 9.0.

 

  • Bad EMF, WMF and PDF graph export quality on Remote Desktop.  Fixed in 9.1 SR3.  
    Two new system variables are introduced. @LLFX8 and
    @LLFX9. Try to set either of them or both to 0 to see if it can fix it.

  • EMF File size huge in 9.1 SR0 to SR2. Fixed in 9.1 SR3.

If data plot's X is from Y data's sampling interval instead of a real X column. Though user re-scaled axis to show only part of the range, the whole data is still included when exporting graph

Worksheet

  • ORG-8799 P1 - Fails to enter millisecond in worksheet in G Origin only
    Set a column as Time format and Display as "HH:mm:ss,##".
    Try to change first cell as 24:00:00,12.
    ==> Millisecond is auto reset to be 0.

    Workaround: Type 14:00:00.12 instead. It can convert to 14:00:00,12 correctly. 

  • ORG-8799 P2 - Fill Column With: A set of Date/Time Values not working with millisecond in German Origin only – Fixed in 9.1 SR1

    Right click a column and choose Fill Column With: A set of Date/Time Values... context menu. 

    Choose Format: Time and Display as HH:mm:ss,##. 

    From and To values will not work. 

...